SLIM-PIR-LUNA

PIR motion detector with lighting feature

SLIM-PIR-LUNA detects motion in the protected area. Additionally, the detector has a set of LEDs to implement the lighting feature.

  • certificate of compliance with the EN 50131 requirements for Grade 2
  • motion detection using passive infrared (PIR) sensor
  • adjustable sensitivity of detection
  • digital motion detection algorithm
  • digital temperature compensation
  • option to enable/disable the creep zone protection
  • wide-angle lens, designed specifically for SLIM LINE detectors
  • option to replace the wide-angle lens with the curtain (CT-CL2) or long-range (LR-CL2) one
  • ability to configure detector operating parameters using the OPT-1 keyfob
  • built-in end-of-line resistors (2EOL: 2 x 1,1 kΩ / 2 x 4,7 kΩ / 2 x 5,6 kΩ)
  • lighting feature implemented with white LEDs
  • remote lighting control or motion activated lighting capability
  • LED indicator
  • selectable color of the LED indicator (7 colors available)
  • LED indicator remote enable/disable
  • remote switching between two levels of PIR sensor sensitivity
  • configuration mode remote enable/disable
  • supervision of motion detection and supply voltage circuit
  • tamper protection against opening of enclosure and removal from mounting
  • adjustable mounting holder (BRACKET D) included

 

The SLIM-PIR-LUNA motion detector received a distinction in the
Dobry Design 2020 competition in the "Modern technologies" category.

More information

 

5 years warranty
EN-50131 GRADE 2 - certificate
SLIM-PIR-LUNA
The actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only.

Documentation

quick installer guide
updated: 2020-06-05
443 KB
general information manual
updated: 2020-02-05
694 KB
mounting template
updated: 2022-03-25
233 KB

Certificates

EN-50131 GRADE 2 - certificate
updated: 2023-02-14
1.81 MB
EU declaration of conformity
updated: 2024-06-06
115 KB

Technical Data

Supply voltage
12 V DC
Detected target velocity
0.3...3 m/s
Operating temperature range
-10°C...+55°C
Recommended mounting height
2.4 m
Standby mode current consumption
13 mA
Max. current consumption
97 mA
Weight
142 g
Maximum humidity
93±3%
Dimensions
62 x 137 x 42 mm
Environmental class according to EN50130-5
II
Alarm signaling time
2 s
Complied with standards
EN 50131-1, EN 50131-2-2, EN 50130-4, EN 50130-5
EOL resistors
2 x 1.1 kΩ / 2 x 4.7 kΩ / 2 x 5.6 kΩ
Warm-up period
30 s
Security grade according to EN50131-2-2
Grade 2
Detection area
20 m x 24 m, 90° (montaż na 2,4 m)
Alarm outputs (NC relay, resistive load)
40 mA / 24 V DC
Tamper outputs (NC relay, resistive load)
40 mA / 24 V DC
Relay contact resistance (alarm output)
26 Ω
Permissible installation height
up to 4 m
Relay contact resistance (tamper output)
26 Ω

Information materials