XD-2 DG

Multipurpose detector

XD-2 is a multipurpose wired detector, which can operate with any alarm control panel. XD-2 can work as: magnetic contact, shock detector, shock detector and magnetic contact, and water flood detector.

XD-2 can also work outdoors, even during adverse weather conditions, if placed inside the OPX-1 enclosure. When XD-2 is installed outside to work in one of the modes which require to use the magnet for proper operation, the OPXM-1 (magnet in a hermetic enclosure) must be used.

It is available in white (XD-2), brown (XD-2 BR) or dark grey (XD-2 DG).

  • option to select detector type with DIP switches
  • mode of operation:
    • magnetic contact:
      • detection of opening of a door, window, etc.
      • input for connecting an NC type wired detector
      • 1 alarm output
    • shock detector:
      • detection of shocks and vibrations accompanying attempts to force a door or window
      • input for connecting an NC type wired detector
      • 1 alarm output
    • shock detector and magnetic contact
      • detection of shocks and vibrations accompanying attempts to force open a door or window, etc.
      • detection of opening a door, window, etc.
      • input for connecting an NC type wired detector
      • 1 or 2 alarm outputs
    • water flood detector
      • detection of flooding in rooms with plumbing
      • input for connecting external flood probe FPX-1 (white), FPX-1 BR (brown) or FPX-1 DG (dark grey) - the probe available separately
      • 1 alarm output
  • LED indicator
  • remote enabling/disabling of LED indicator
  • supply voltage control
  • tamper protection against enclosure opening and removal from mounting surface
  • 2 magnets included (for surface and flush mounting)

 

XD-2 DG
The actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only.

Documentation

quick installer guide
updated: 2021-11-30
828 KB
general information manual
updated: 2021-11-30
568 KB
mounting template
updated: 2021-11-05
53 KB

Certificates

EU declaration of conformity
updated: 2024-06-06
116 KB

Technical Data

Operating temperature range
-10°C...+55°C
Standby mode current consumption
12,5 mA
Max. current consumption
14 mA
Weight
46 g
Maximum humidity
93±3%
Environmental class according to EN50130-5
II
Detector enclosure dimensions
20 x 102 x 23 mm
Complied with standards
EN 50130-4, EN 50130-5, EN 50131-1, EN 50131-2-6
Security grade according to EN50131-2-6
Grade 2
Magnet enclosure dimensions - surface mounting
15 x 52 x 6 mm
Magnet pad dimensions - surface mounting
15 x 52 x 6 mm
Magnet pad dimensions - recessed mounting
ø10 x 28 mm
Maximum gap - surface magnet (magnetic contact)
15 mm
Maximum gap - recessed magnet (magnetic contact)
19 mm
Tamper outputs (NC)
40 mA / 24 V DC
Power supply voltage (±25%)
12 V DC
S alarm outputs (NC relay, resistive load)
40 mA / 24 V DC
Relay contact resistance (NC alarm output)
26 Ω
Relay contact resistance (S alarm output)
26 Ω
SNS input sensitivity (NC type detector)
150 ms
SNS input sensitivity (flood probe)
1 s
Detection range (depending on surface type) (shock detector)
up to 3 m
NC alarm outputs (NC relay, resistive load)
40 mA / 24 V DC

Information materials

1catalogue

4technical data

5product data sheet