SLIM-R-DUAL-PRO

Ceiling dual-tech motion detector with IR anti-masking (recessed)

SLIM-R-DUAL-PRO is an indoor motion detector from the SLIM LINE series, designed for recessed ceiling mounting. Is it an excellent solution for rooms with suspended ceilings. With its 360° detection coverage, it is well suited for monitoring shops, warehouses, and other spaces where a ceiling-mounted detector facing downward provides more effective area coverage than a wall-mounted detector.

This model is also available for surface mounting (SLIM-S-DUAL-PRO).

  • compliant with the EN 50131 Grade 3 requirements
  • motion detection using two sensors: passive infrared (PIR) and microwave (MW)
  • active IR anti-masking compliant with EN 50131-2-4 for Grade 3 (delay: 1 s / 60 s)
  • maximum detection area:
    • ø 8 m / 50 m² – mounting height 2,4 m
    • ø 9.3 m / 79 m² – mounting height 3,5 m
  • digital motion detection algorithm for both sensors
  • digital temperature compensation
  • adjustable detection sensitivity for both sensors
  • separate sensor testing feature
  • digital filtering of signals received by the microwave sensor, ensuring immunity to interference caused by the power grid and discharge lamps
  • selectable operating modes: basic, advanced, PIR, or MW
  • detector operating parameter configuration:
    • on-board buttons
    • OPT-1 remote keyfob
  • built-in EOL resistors: 1,1 kΩ, 4,7 kΩ, 5,6 kΩ
  • LED indicator:
    • selectable colour
    • remote on/off control
  • remote enable/disable of configuration mode
  • supervision of the motion detection circuit
  • 12 V DC power supply (±15%)
  • power supply monitoring
  • tamper protection against enclosure opening and detector tilt (optional, when tilt detection is enabled)
  • installation in suspended ceiling
SLIM-R-DUAL-PRO
The actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only.

Documentation

general information manual
updated: 2026-05-19
823 KB
quick installer guide
updated: 2026-05-11
497 KB

Technical Data

Supply voltage
12 V DC
Detected target velocity
0,2...3 m/s
Operating temperature range
-10°C...+55°C
Recommended mounting height
2,4…3,5 m
Standby mode current consumption
18 mA
Max. current consumption
50 mA
Weight
141 g
Maximum humidity
93±3
Dimensions
ø 130 x 42 mm
Environmental class according to EN50130-5
II
Alarm signaling time
2 s
Complied with standards
EN 50131-1, EN 50131-2-4, EN 50130-4, EN 50130-5
Microwave frequency
24,125 GHz
Security grade according to EN50131-2-4
Grade 3
Warm-up period
30 s
Alarm outputs (NC relay, resistive load)
40 mA / 24 V DC
Tamper outputs (NC relay, resistive load)
40 mA / 24 V DC
Anti-masking outputs (NC relay, resistive load)
40 mA / 24 V DC
Relay contact resistance (alarm output)
26 Ω
Relay contact resistance (tamper output)
26 Ω
Relay contact resistance (anti-masking output)
26 Ω
EOL resistors
2 x 1,1 / 2 x 4,7 / 2 x 5,6 kΩ

Information materials

1catalogue

4technical data

5product data sheet