GPRS-T6
GPRS/SMS reporting module with buffer power supply
The versatile GPRS-T6 communication unit is designed for GPRS and SMS monitoring from any alarm control panel or other device. An additional functionality of the GPRS-T6 unit is the remote control of the module's outputs, which allow for e.g. activation or deactivation of the alarm system stand-by mode using SMS. The built-in buffer power supply in the GPRS-T6 module allows continued communication even if the main power supply fails.
- 8 monitoring triggering or message inputs
- dedicated inputs for alarm system failure signals
- dedicated input for AC power supply monitoring
- 4 outputs with remote control option
- automatic switching to SMS in case of lack of GPRS signal
- SMS/CLIP messaging
- sending test transmission using CLIP
- communication failure signalling
- built-in 2 A buffer power supply
discontinued
The actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only.
Documentation
Software
Technical Data
Environmental class
II
Number of OC outputs
4
Power supply type
A
Number of inputs (zones)
8+3
Power supply rating
2 A
Board dimensions
120 x 68,5 mm
Operating temperature range
-10...+55 °C
Current consumption from 230 V mains - standby
110 mA
Current consumption from 230 V mains - maximum
150 mA
Current consumption from battery - maximum
400 mA
Current consumption from battery - standby
120 mA
Recommended transformer type
TR40VA (40VA / 18VAC)
Output voltage range
10,5…13,8 V DC
Battery failure voltage threshold (±10%)
11 V
Battery cut-off voltage (±10%)
10,5 V
Number of outputs power
1
Supply voltage (±10%) [V AC]
18 V AC
Battery charging current (±20%)
250 mA
Device + housing weight
1012 g
Permissible voltage on the ACE
up to 25 V
Current carrying capacity of the output +12V
500 mA
Current carrying capacity of the output operating as a malfunction indicator
50 mA